Load cell M740 (100t..600t)

 

  • Compression load cell, selfcentering column
  • 3000 divisions O.I.M.L. R60 class C
  • Stainless steel construction
  • Hermetically welded, protection class IP 68 ( EN60529 ).
  • Pre-corner adjustment optimized for multicell systems.
  • Lighting protection.
  • Available in ATEX EX version (optional)
  • Applications : High capacity weighing systems, truck scales.

Technical documentation

Nominal capacities 100-200-400-600 t
Accuracy class 1000 n. OIML
Minimum dead load 0 %Ln
Service load 120 %Ln
Safe load limit 150 %Ln
Total error ± 0.05 %Sn
Repeatability error < ± 0.015 %Sn
Temperature effect on zero < ± 0.01 %Sn/5K
Temperature effect on sensitivity < ± 0.018 %Sn/5K
Creep error (30 minutes) < ± 0.048 %Sn/5K
Temperature compensation -10 to +40 ° C
Temperature limits -50 to +80 ° C
Nominal sensitivity (Sn) 2 ± 0.5% mV/V
Nominal input voltage 10 V
Max. input voltage 15 V
Input impedance 800 ± 5 Ohm
Output impedance 705 ± 5 Ohm
No load output  ± 2 %Sn
Insulation resistance > 5000 MOhm
Max.deflection (at Ln) 1,2 - 2,6 mm