Tension-compression load cell. Measuring element from stainless steel. 3000 divisions O.I.M.L. R60 class C. Protected IP 68 (DIN 40050). Available in ATEX EX version (optional).
Load cell M650



Technical documentation
Nominal capacities | 250-500-1000-2000-5000-7500 | kg |
---|---|---|
Accuracy class | 3000 | n. OIML |
Minimum dead load | 0 | %Ln |
Service load | 150 | %Ln |
Safe load limit | 200 | %Ln |
Total error | < ± 0.017 | %Sn |
Repeatability error | < ± 0.015 | %Sn |
Temperature effect on zero | < ± 0.01 | %Sn/5K |
Temperature effect on sensitivity | < ± 0.006 | %Sn/5K |
Creep error (30 minutes) | < ± 0.016 | %Sn/5K |
Temperature compensation | -10 to +40 | ° C |
Temperature limits | -40 to +95 | ° C |
Nominal sensitivity (Sn) | 2 ± 10% | mV/V |
Nominal input voltage | 10 | V |
Max. input voltage | 15 | V |
Input impedance | 400 ± 20 | Ohm |
Output impedance | 350 ± 3 | Ohm |
No load output | < ± 2 | %Sn |
Insulation resistance | > 5000 | MOhm |
Max.deflection (at Ln) | <0.5 | mm |
Tension accessories : Towing attachment (M12x1.75, M20x1.5, M24x2)+TE12,20,24.
Dimmensions in mm.