Load cell M540

Measuring element from steel alloy. 3000 divisions O.I.M.L. R60 class C. Protected IP 66 (DIN 40050). Protected against corrosion by nickel-plated treatment. 6 wire (sense) electrical connection.

  • Tension load cell
  • Measuring element from steel alloy
  • 3000 divisions O.I.M.L. R60 class C
  • Protected IP 66 (DIN 40050)
  • Protected against corrosion by nickel-plated treatment
  • 6 wire (sense) electrical connection

Technical documentation

Nominal capacities 2000-3000-6000-10000 kg
Accuracy class 3000 n. OIML
   
Minimum dead load 0 %Ln
Ultimate load limit 300 %Ln
Total error < ± 0.017 %Sn
Repeatability error < ± 0.015 %Sn
Temperature effect on zero < ± 0.01 %Sn/5K
Temperature effect on sensitivity < ± 0.006 %Sn/5K
Creep error (30 minutes) < ± 0.016 %Sn/5K
Temperature compensation -10 až +40 ° C
Temperature limits -20 až +70 ° C
Nominal sensitivity (Sn) 2 ± 10% mV/V
Nominal input voltage 10 V
Max. input voltage 15 V
Input impedance 400 ± 20 Ohm
Output impedance 350 ± 3 Ohm
No load output < ± 2 %Sn
Insulation resistance > 5000 MOhm
Max.deflection (at Ln) 0.3 - 0.4 mm

Overdimensioning properly the load cell is advised. Choose the nominal capacity taking into account that the security factor will be determined by the ratio between ultimate load and the user maximum working load.