Load cell M460

img

Double shear load cell. Measuring element from stainless steel. Hermetically sealed, fully welded. Protected IP 68 (DIN 40050). Easy installation. Available in ATEX EX version (optional). Application: Tanks and silos weighing systems with highly linear and low profile requirements.

  • Double shear load cell
  • Measuring element from stainless steel
  • Hermetically sealed, fully welded
  • Protected IP 68 (DIN 40050)
  • Easy installation
  • Available in ATEX EX version (optional)
  • Application: Tanks and silos weighing systems with highly linear and low profile requirements

 

Technical documentation

Nominal capacities 5, 10, 20, 30, 50, 75 a 100 t
Accuracy class 3000 n. OIML
Minimum dead load 0 %Ln
Service load 150 %Ln
Safe load limit 200 %Ln
Total error < ± 0.017 %Sn
Repeatability error < ± 0.015 %Sn
Temperature effect on zero < ± 0.01 %Sn/5K
Temperature effect on sensitivity < ± 0.006 %Sn/5K
Creep error (30 minutes) < ± 0.016 %Sn/5K
Temperature compensation -10 až +40 ° C
Temperature limits -30 až +70 ° C
Nominal sensitivity (Sn) 2 ± 0.1% mV/V
Nominal input voltage 10 V
Max. input voltage 15 V
Input impedance 800 ± 30 Ohm
Output impedance 700 ± 3 Ohm
No load output < ± 2 %Sn
Insulation resistance > 5000 MOhm
Max.deflection (at Ln) 0.6 - 1 mm