Load cell M300

img
  • Double bending beam load cell
  • Fully stainless steel
  • 3000 divisions O.I.M.L. R60 class C / 6000 d for capacities 50kg .. 250kg
  • Hermetically sealed, fully welded
  • Protected IP 68 (DIN 40050)
  • Available in ATEX EX version (optional)

Technical documentation

Nominal capacities 5-10-20-30-50-75-
-100-150-200-250-300-500
kg
Accuracy class 3000 / 6000 (50 .. 250kg) n. OIML
Minimum dead load 0 %Ln
Service load 150 %Ln
Safe load limit 200 %Ln
Total error < ± 0.017 %Sn
Repeatability error < ± 0.015 %Sn
Temperature effect on zero < ± 0.01 %Sn/5K
Temperature effect on sensitivity < ± 0.006 %Sn/5K
Creep error (30 minutes) < ± 0.016 %Sn/5K
Temperature compensation -10 až +40 ° C
Temperature limits -20 až +50 ° C
Nominal sensitivity (Sn) 2 ± 10% mV/V
Nominal input voltage 10 V
Max. input voltage 15 V
Input impedance 400 ± 20 Ohm
Output impedance 350 ± 3 Ohm
No load output < ± 2 %Sn
Insulation resistance > 5000 MOhm
Max.deflection (at Ln) 0.2 - 0.4 mm