Load cell M190

img

Nominal capacity: 15-20-30-50-75-120-200-250-350-400 kg. Double bending beam load cell. Versions: (1) 190a - measuring element from steel alloy, 4000 divisions O.I.M.L. R60 class C, protected IP 66 (EN 60529); (2) 190i - measuring element from inox, 3000 divisions O.I.M.L. R60 class C, protected IP 68 (EN 60529). ATEX option. Aplications: direct platform up to 600x600mm or 800x800mm, filling scales.

  • Nominal capacity: 15*-20*-30*-50-75-120-200-250-350-400 kg . *) available only for the inox version.
  • Double bending beam load cell
  • Versions:
    1. 190a - measuring element from steel alloy
      4000 divisions O.I.M.L. R60 class C
      protected IP 66 (EN 60529)
    2. 190i - measuring element from inox
      3000 divisions O.I.M.L. R60 class C
      protected IP 68 (EN 60529) and IP 69K (EN20653) 3000d. Option ATEX.
  • Aplications:
    • direct platform up to 600x600mm or 800x800mm
    • filling scales

 

Technical documentation

Nominal capacities 15-20-30-50-75-120-200-250-350-400 kg
Accuracy class 3000/4000 n. OIML
Minimum dead load 0 %Ln
Service load 150 %Ln
Safe load limit 200 %Ln
Total error < ± 0.017 %Sn
Repeatability error < ± 0.01 %Sn
Temperature effect on zero < ± 0.01 %Sn/5K
Temperature effect on sensitivity < ± 0.006 %Sn/5K
Creep error (30 minutes) < ± 0.016 %Sn/5K
Temperature compensation -10 až +40 ° C
Temperature limits -20 až +70 ° C
Nominal sensitivity (Sn) 2 ± 10% mV/V
Nominal input voltage 10 V
Max. input voltage 15 V
Input impedance 400 ± 20 Ohm
Output impedance 350 ± 3 Ohm
No load output < ± 2 %Sn
Insulation resistance > 5000 MOhm
Max.deflection (at Ln) 0.3 - 0.5 mm