DAT-500

Very reliable and precise indicator and data transmitter. It can feed up to 6 load cells through a junction box. Available in Modbus RTU as standard. Option of Profibus DP. Set up data can be stored for later replication in the 1008 tester and calibrator.

Technical documentation

  • 96x48x120 mm ( L x H x D). Mounting on panel, manhole: 92x44
  • Material : ABS
  • Protection DAT400(front) : IP-20 DAT500(front): IP-51
  • Weight : 230 g
  • Working temperature : -10 až +40°C
  • Power supply : 24 VDC ± 15%
  • Power equirement : 5 W.
  • Dislay and setting : 6x 7 segment LED digit, height 1,44 mm -- 4x red status LED --- 4x membrane buttons.
  • Conversion response : 50 Hz (without filtration)
  • Internal discernment : 60.000 poits
  • Sensibility : 0,02 µV/division
  • Linearity : < 0,01% on the range
  • Temperature effect : < 0,001% on the range/°C
  • Converter A/D : 24 bit
  • Decimal point : 0,0 - 0,00 - 0,000 optional.
  • For 6 load cells (350 Ohmů) 4 or 6 wire
  • Output interface RS-232, RS 422 or RS 485.
  • 2 digital (logical) input (opto-izolated, 24 VDC PNP - requierement external supply)
  • 2 digital output ( semiconductor relay, max. 24VDC/100 mA each)
  • 1 analog output (0-10 VDC, max. resistance 10 kOhm or 4-20 mA , min. resistance 300 Ohm)
  • Setting possible using buttons on front panel or through RS 232 interface and program INOVATION.
  • Both direct or indirect calibration are possible (the second mentioned is suitable for calibration of forces, big containers e.g. which cannot be calibrated directly ).
  • Power supply source for DAT 400/500 Mod. 121 is recommended to be used