Load cell M190 ATEX

  • Nominal capacity: 15-20-30-50-7
  • 5-120-200-250-350-400 kg.Double bending beam load cell.
  • Measuring element from inox, 3000 divisions O.I.M.L. R60 class C, protected IP 68 (EN 60529).
  • Aplications: direct platform up to 600x600mm or 800x800mm, filling scales.
  • Zone 0-1-2 (gas) and 20-21-22 (dust)

Technical documentation

 

Nominal capacities 50-75-120-200-250-350-400 kg
Accuracy class 3000 n. OIML
Minimum dead load 0 %Ln
Service load 150 %Ln
Safe load limit 200 %Ln
Total error < ± 0.017 %Sn
Repeatability error < ± 0.01 %Sn
Temperature effect on zero < ± 0.01 %Sn/5K
Temperature effect on sensitivity < ± 0.006 %Sn/5K
Creep error (30 minutes) < ± 0.016 %Sn/5K
Temperature compensation -10 až +40 ° C
Temperature limits -20 až +70 ° C
Nominal sensitivity (Sn) 2 ± 10% mV/V
Nominal input voltage 10 V
Max. input voltage 15 V
Input impedance 400 ± 20 Ohm
Output impedance 350 ± 3 Ohm
No load output < ± 2 %Sn
Insulation resistance > 5000 MOhm
Max.deflection (at Ln) 0.3 - 0.5 mm